Technical Specifications of Exide Inverterz Star
Description | STAR 12V 650VA | STAR 12V 850VA | STAR 12V 1050VA | STAR 24V 1450VA |
---|---|---|---|---|
Output Voltage at No Load | 220V ± 7V AC | |||
Output Frequency | 50Hz ± 1Hz | |||
Output Wave Form | Pure Sine Wave | |||
Nominal Battery Voltage | 12V DC | 24V DC | ||
Battery Low Cut Off | 10.5V ± 0.2V DC | 21.0V ± 0.4V DC |
Charging Mode
Model | STAR 12V 650VA | STAR 12V 850VA | STAR 12V 1050VA | STAR 24V 1450VA |
---|---|---|---|---|
Maximum Charging Current (NC) | 11Amps ± 1Amp | 12Amp ± 1Amp | 13Amp ± 1Amp | 12Amp ± 1Amp |
Maximum Charging Current (HC) | 15Amps ± 1Amp | 17Amp ± 1Amp | 18Amp ± 1Amp | 17Amp ± 1Amp |
Boost Charging Voltage | 14.4V ± 0.2V DC | 28.8V ± 0.4V DC | ||
Trickle Charging Voltage | 13.7V ± 0.2V DC | 27.4V ± 0.4V DC | ||
Charging Current at 120V Mains Input | 8-10 Amp Charging Current* | |||
Charging Over Time Mains to Back-up (@ UPS Mode) | ? 10 msec | |||
Charging Over Time Back-up to Mains (@ UPS Mode) | ? 10 msec | |||
Input Voltage Range (@ UPS Mode) | 180V - 270V ± 10V AC | |||
Change Over Time Mains to Back-up (@ Normal Mode) | ? 40 msec | |||
Change Over Time Back-up to Mains (@ Normal Mode) | ? 10 msec | |||
Input Voltage Range (@ Normal Mode) | 90V - 300V ± 10V AC |